TM 9-2350-260-20-1-2
FUEL TANK (LEFT AND RIGHT) CONDENSATE RELIEF VALVE REPLACEMENT (Sheet 1 of 4)
PROCEDURE INDEX
PROCEDURE
PAGE
Removal
7-172
Cleaning and Inspection
7-174
Installation
7-174
TOOLS:
1-3/4 in. open end wrench
6 in. ruler
Retaining ring pliers
Slip joint pliers
Ratchet with 1/2 in. drive
15/16 in. socket with 1/2 in. drive
SUPPLIES:
Dry cleaning solvent ([tem 54, Appendix D)
Preformed packing (MS28775-214)
Rags (Item 65, Appendix D)
REMOVAL:
1.
Using socket, loosen bolts (A)
securing top assembly doors (B).
Open doors (B) to gain access to
left and right fuel tanks.
Go on to Sheet 2
TA148247
7-172