TM 9-2350-260-20-1-3
GENERATOR ELECTRICAL LEADS REPLACEMENT (2A ENGINE)(Sheet 5 of 5)
6.
Install lead (A) into clamps (L).
7.
Using 1/2 inch socket, install and tighten screws (M) and new lockwashers (N) securing clamps (L).
8.
Position end of lead (A) onto stud of generator.
9.
Using 9/16 inch wrench, install and tighten new self-locking nut (P) and washers (Q) securing lead (A).
10. Install powerplant (page 5-14).
End of Task
TA147403