TM 9-2350-260-20-1-3
ENGINE STARTER WIRING HARNESS REPLACEMENT (2A ENGINE) (Sheet 4 of 4)
7.
Using flat-tip screwdriver, install small cable
(K) onto bottom front mount of relay solenoid
(L) with screw and external tooth lockwasher
(M).
8.
Install small cable (N) and two ends (P) and
(Q) of cable (B) onto lower terminal of starter
relay solenoid (L) with nut and two new
lockwashers (R).
Using 3/4 inch socket on nut
and two lockwashers (R), tighten nut.
9.
Install ground strap (S), two ends (T) and (U)
of cable (C), and small cable (V) onto terminal
on starter motor (W) with nut and two new
lockwashers (X).
Using 3/4 inch socket on nut
and lockwashers (X), tighten nut.
10. Coat all exposed connections with glyptol
(Item 38, Appendix D).
11. Install powerplant (page 5-14).
End of Task
TA147411
10-379