TM 9-2350-260-20-1-3
INTERPHONE CABLE RECEPTACLE DUST CAP AND GASKET REPLACEMENT (Sheet 1 of 2)
TOOLS:
Cross-tip screwdriver
6 in.
adjustable wrench
SUPPLIES:
Lockwasher (MS35338-42)(4 required)
PRELIMINARY PROCEDURE:
Disconnect rear interphone cable (page 10-393)
REMOVAL
1.
Remove dust cap (A) from inside of interphone box
(B).
2.
Place wrench on nut (C) of interphone box (B).
3.
Using screwdriver, remove four screws (D) and
lockwashers (E) securing connector (F) and gasket
(G) to rear of interphone box (B).
Throw
lockwashers away.
4.
Remove connector (F), gasket (G), and nut (C).
Go on to Sheet 2
TA147429
10-397