TM-9-2350-261-20-2

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 2 OF 4

  TM-9-2350-261-20-2 - Page 396 of 1008

TM 9-2350-261-20-2
REPLACE REAR MAIN WIRING HARNESS (M1064 ONLY) — Continued
0288 00
0288 00-12
NOTE
The 200 amp and 100 amp distribution boxes are similar. Removal of most lead wires are the
same. 200 amp is shown. Do Step 52 for 200 amp only.
52. Disconnect circuit 37 lead (1) from master switch panel lead (2).
53. Remove eight screws (3), washers (4), and locknuts (5) from master switch panel (6). Separate panel from distribution
box (7). Discard locknuts.
54. Remove locknut (8), screw (9), circuit 400 (10), circuit 2 (11), and circuit 6 (12) leads from bus bar (13) on master
switch (14). Discard locknut.
55. Remove circuit 400 lead (10) and grommet (15) from distribution box (7). Discard grommet.
56. Disconnect circuit 450 lead (16) from lower circuit breaker (17).
57. Disconnect circuit 450B lead (18) from upper circuit breaker (19).
58. Remove circuit 450 (16) and 450B (18) leads and two grommets (20) from distribution box (7). Discard grommets.


Back to Top