REPLACE DIFFERENTIAL HIGH OIL TEMPERATURE SWITCH
0318 00
THIS WORK PACKAGE COVERS:
Removal (page 0318 00-1).
Installation (page 0318 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Materials/Parts
Sealing compound (WP 0782 00, Item 60)
Personnel Required
Unit Mechanic
Equipment Condition
Engine stopped/shutdown (see your -10)
Carrier blocked (see your -10)
Differential drained (WP 0120 00)
Trim vane lowered and power plant front access door
open (see your -10)
REMOVAL
1.
Disconnect circuit 328 lead (1) from differential high oil temperature switch (2).
2.
Remove switch (2) from tee (3).
031800-1