TM 9-2350-261-20-2
REPLACE DIFFERENTIAL HIGH OIL TEMPERATURE SWITCH — Continued
0318 00
INSTALLATION
WARNING
Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These
compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you
dizzy and irritate your eyes and throat.
Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes.
Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves.
1.
Coat threads of switch (2) with sealing compound.
2.
Install switch (2) in tee (3). Tighten switch.
3.
Connect circuit 328 lead (1) to switch (2).
FOLLOW-THROUGH STEPS
1.
Refill differential (WP 0120 00).
2.
Start engine (see your -10). Check for oil leaks at differential high oil temperature switch.
3.
Stop/shutdown engine (see your -10).
4.
Close power plant front access door and raise trim vane (see your -10).
END OF TASK
0318 00-2