TM 9-2350-261-20-2
REPLACE BLOWER SWITCH (M577A2 AND M1068 ONLY)
0336 00
THIS WORK PACKAGE COVERS:
Removal (page 0336 00-1).
Installation (page 0336 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Materials/Parts
Locknut (8)
Personnel Required
Unit Mechanic
Equipment Condition
Engine stopped (see your -10)
Battery ground lead disconnected (WP 0294 00)
REMOVAL
1.
Remove eight locknuts (1), washers (2), screws (3), and master switch panel (4) from distribution box (5). Discard
locknuts.
2.
Disconnect two circuit 59 leads (6) from rear of blower switch (7).
3.
Remove two screws (8) and switch (7) from panel (4).
4.
Inspect gasket (9). Replace if damaged.
033600-1