TM 9-2350-261-20-2
REPLACE REAR UTILITY RECEPTACLE CIRCUIT BREAKERS (M577A2
AND M1068 ONLY) — Continued
0333 00
INSPECTION-ACCEPTANCE AND REJECTION CRITERIA
1.
Clean leads. Replace frayed, cracked, or broken leads (WP 0312 00).
2.
Clean connectors. Replace cracked or broken connectors (WP 0312 00).
3.
Inspect gasket on flange of distribution box. Replace if damaged.
INSTALLATION
1.
Place circuit breaker (1) in distribution box (2). Secure with two screws (3) and nuts (4).
2.
Place circuit breaker (5) in distribution box (2). Secure with two screws (3) and nuts (4).
3.
Connect circuit 10 lead (6) and circuit 37A lead (7) to circuit breaker (1).
4.
Connect circuit 37B lead (8) and circuit 10 lead (9) to circuit breaker (5).
5.
Place panel (10) on distribution box (2). Secure with eight screws (11), washers (12), and new locknuts (13).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0294 00).
2.
Turn MASTER SWITCH to ON (see your -10).
3.
Check for power at utility outlet receptacles (WP 0044 00).
4.
Turn MASTER SWITCH to OFF (see your -10).
END OF TASK