TM 9-2350-261-20-2
REPLACE REAR UTILITY RECEPTACLE CIRCUIT BREAKERS
(M577A2 AND M1068 ONLY)
0333 00
THIS WORK PACKAGE COVERS:
Removal (page 0333 00-1).
Inspection-Acceptance and Rejection Criteria (page 0333 00-2).
Installation (page 0333 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Materials/Parts
Lock
nu t (8 )
Personnel Required
Unit Mechanic
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Battery ground lead disconnected (WP 0294 00)
REMOVAL
NOTE
If you want to remove only the left circuit breaker, skip Step 3. If you want to remove only the
right circuit breaker, skip Step 2.
1.
Remove eight locknuts (1), washers (2), screws (3), and panel (4) from distribution box (5). Discard locknuts.
2.
Disconnect circuit 10 lead (6) and circuit 37A lead (7) from left circuit breaker (8).
3.
Disconnect circuit 37B lead (9) and circuit 10 lead (10) from right circuit breaker (11).
4.
Remove four nuts (12), screws (13), and circuit breakers (8) and (11) from distribution box (5).
033300-1