TM 9-2350-261-20-2
REPLACE TRANSFER GEARCASE RESILIENT MOUNT — Continued
0342 00
CLEAN, INSPECT, AND REPAIR
1.
Clean mount with cleaning compound.
2.
Check mounts. Replace mount that is cracked, bent, or worn.
INSTALLATION
1.
Use remover and replacer tool to install mount (1) in transfer gearcase (2).
FOLLOW-THROUGH STEPS
1.
Install power plant in carrier (WP 0131 00).
END OF TASK
0342 00-2