TM 9-2350-261-20-2
REPLACE ENGINE POWER DISCONNECT — Continued
0408 00
ADJUSTMENT
1.
Lift lock (1) on control lever (2). Push lever in as far as it will go. This disconnects engine from the rest of power plant.
2.
Loosen two screws (3) and nuts (4) that secure two supports (5), lock (1), spring (6), and bushing (7) to lever (2).
3.
Move two supports (5) until the clearance between lock (1) and guide (8) is 1/32–3/32 in (0.8 mm-2.4 mm).
4.
Tighten two screws (3) and locknuts (4).
FOLLOW-THROUGH STEPS
WARNING
Loose clothing is dangerous around moving belts and pulleys. You could get badly hurt if your
clothes get caught in moving parts.
1.
Check engine disconnect operation. Push control lever in. Then start engine (see your -10). Fan and fan belts should not
work. Stop engine. Pull out control lever. Then start engine (see your -10). Fan and fan belts should operate properly.
2.
Install power plant rear access panel (WP 0431 00, WP 0432 00, or WP 0433 00).
3.
Install drive’s power plant access panel (WP 0430 00).
4.
Raise and lock ramp (see your -10).
5.
Stop/shutdown engine (see your -10).
END OF TASK
0408 00-3/4 blank