TM 9-2350-261-20-3
REPLACE SMOKE GRENADE LAUNCHER WIRING HARNESS (M113A2,
M1059, AND M901A1 ONLY) — Continued
0577 00
4.
Install clamp (23) on wiring harness (14). Secure clamp to bulkhead with screw (21), two washers (22), and new
locknut (20).
5.
Secure circuit 7 lead (19) to bulkhead with screw (17), two washers (18), and new locknut (16).
6.
Install four clamps (13) on wiring harness (14) and intercom cable assembly (15). Secure clamps to bulkhead with
four screws (11) and new lockwashers (12).
7.
Secure circuit 6L lead (8) and circuit 6 lead (9) to bus bar (10) with screw (6) and two new lockwashers (7).
8.
Install master switch panel (5) to distribution box (4) with eight screws (2), washers (3), and new locknuts (1).
0577 00-8