TM 9-2350-261-20-3
REPLACE RAMP PUMP TO HYDRAULIC TANK STRAINER TUBE — Continued
0580 00
CLEAN, INSPECT, AND REPAIR
1.
Check tube. Replace cracked or distorted tube.
INSTALLATION
1.
Install tube (6) on elbow (12) and ramp pump (13).
2.
Place clamp (8) on tube (6). Align clamp (8) with clamp (10) on hose (11). Secure with screw (7) and new locknut (9).
3.
Place clamp (2) on tube (6). Align clamp (2) with clamp (4) on cable (5). Secure with screw (1) and new locknut (3).
058000-3