REPLACE RAMP PUMP TO HYDRAULIC TANK STRAINER TUBE — Continued
0580 00
REMOVAL
1.
Remove screw (1), clamp (2), and locknut (3) from clamp (4) on tachometer cable (5). Remove clamp (2) from tube
(6). Discard locknut.
2.
Remove screw (7), clamp (8), and locknut (9) from clamp (10) on ramp pump-to-relief valve hose (11). Remove clamp
(8) from tube (6). Discard locknut.
WARNING
Fire Resistant Hydraulic fluid (FRH) is toxic if absorbed through skin or ingested.
Do not service hydraulic system when FRH is hot or pressurized.
Wear gloves and avoid contact with skin.
If FRH contacts skin, wash immediately with soap.
If FRH gets into eyes, wash with lots of water for 15 minutes and get medical attention.
If FRH is swallowed, get medical attention.
3.
Remove tube (6) from elbow (12) and ramp pump (13).