TM 9-2350-261-20-3
REPLACE RAMP PUMP TO PRESSURE RELIEF VALVE HOSE — Continued
0581 00
REMOVAL
1.
Remove screw (1), clamp (2), and locknut (3) from clamp (4) on ramp-to-strainer tube (5). Remove clamp (2) from
hose (6). Discard locknut.
2.
Remove screw (7), tab washer (8), and clamp (9) from transfer gearcase. Discard tab washer.
3.
Remove clamp (9) from hose (6).
WARNING
Fire Resistant Hydraulic fluid (FRH) is toxic if absorbed through skin or ingested.
Do not service hydraulic system when FRH is hot or pressurized.
Wear gloves and avoid contact with skin.
If FRH contacts skin, wash immediately with soap.
If FRH gets into eyes, wash with lots of water for 15 minutes and get medical attention.
If FRH is swallowed, get medical attention.
4.
Remove hose (6) from ramp pump elbow (10) and tee (11).
0581 00-2