REPLACE PERSONNEL HEATER ASSEMBLY (M1064 ONLY) — Continued
REMOVAL
1.
Disconnect wiring harness (1) from heater (2).
2.
Loosen clamp (3) on heater intake pipe (4).
3.
Loosen clamp (5) on heater exhaust pipe (6).
NOTE
For A20 heaters, ground strap is attached to top of heater.
4.
Remove screw (7), lockwasher (8), and ground strap (9) from heater (2). Discard lockwasher.
5.
Loosen two clamps (10). Remove heater (2) and shield (11) from carrier. Remove clamps (3) and (5) from heater.
0621 00-2
0621 00
TM 9-2350-261-20-3