TM 9-2350-261-20-4
REPLACE POWER CONTROL ENCLOSURE AC AND DC METERS
AND LIGHT INDICATORS (M1068 ONLY)
0729 00
THIS WORK PACKAGE COVERS:
Removal (page 0729 00-1).
Installation (page 0729 00-3).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Materials/Parts
Primer (WP 0782 00, Item 54)
Sealing compound (WP 0782 00, Item 67)
Locknut (6)
Lockwasher (10)
Lockwasher (2)
Personnel Required
Power-Generation Equipment Repairer 52D10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
All external power disconnected (TM 11-7010-256-
12&P)
Battery ground lead disconnected (WP 0294 00)
REMOVAL
1.
Remove ten screws (1), lockwashers (2), and lower faceplate assembly (3) from power enclosure (4). Discard
lockwashers.
2.
Remove nut (5) and safety cover (6) from terminal 2 on meter M1 (7). Unwrap velcro strap (8) from around local wiring.
072900-1