TM 9-2350-261-20-4
REPLACE INVERTER HOUSING A2 TERMINAL BLOCKS TB1 AND
TB2 (M1068 ONLY) — Continued
0728 00
REMOVAL
1.
Remove ten screws (1), lockwashers (2), and cover (3) from inverter housing (4). Discard lockwashers.
NOTE
Tag all leads before disconnecting.
2.
Loosen two set screws (5) and remove cable W6 lead E2 (6) and two inverter leads E4 (7) from terminal block TB1 (8).
3.
Remove ten screws (9), cable W5 leads E1 through E5 (10), and six inverter leads (11) from terminal block TB2 (12).
0728 00-2