TM 9-2350-277-20-1
MSD/ICE TEST 69 STARTER NEGATIVE CABLE VOLTAGE DROP
DIAGNOSTIC TROUBLESHOOTING
0149 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
Electrical Connector Pliers (WP 0926 00, Item 31)
MSD/ICE Test Set (WP 0926 00, Item 61)
Jumper Wire
Personnel Required
Mechanic
References
TM 9-6625-2301-14&P
Equipment Condition
Engine stopped (TM 9-2350-277-10)
Carrier blocked (TM 9-2350-277-10)
Power plant access door open (TM 9-2350-277-10)
Driver’s power plant access panel removed
(WP 0441 00)
T
1.
Remove plug W1P1 from MSD jack J1.
2.
Hook up MSD to carrier batteries. See TM 9-6625-2301-14&P.
3.
Set up Test 89. See TM 9-6625-2301-14&P.
4.
Measure resistance between W1P1 (1), pin W (2) and
harness 12354593 circuit 779 terminal E4 (3) on battery
negative terminal (4).
5.
Measure resistance between W1P1 (1), pin M (5) and harness
12354672 circuit 773 terminal E2 (6) on starter ground stud (7).
6.
Does MSD read more than one ohm either time?
TN
1.
Faulty MSD.
2.
Notify supervisor.
014900-1