TM 9-2350-277-20-1
MSD/ICE TEST 69 STARTER NEGATIVE CABLE VOLTAGE DROP DIAGNOSTIC
TROUBLESHOOTING — Continued
0149 00
Y
1.
Remove plug W1 P2 (1) from MSD/ICE distribution
box jack J2 (2).
2.
Measure resistance between MSD/ICE distribution box jack
J2 (2), pin W (3) and harness 12354593 circuit 779 terminal
E4 (1) on battery negative terminal.
3.
Measure resistance between MSD/ICE distribution box
jack J2 (2), pin M (4) and harness 12345472 circuit 773
terminal E2 on starter.
4.
Does MSD read more than one ohm either time?
YN
1.
Faulty W1 cable. Beyond unit
maintenance repair.
2.
Notify supervisor.
2Y
1.
Remove harness 12354593 P1 (1) from MSD/ICE
distribution box jack J1 (2).
2.
Measure resistance between 12354593 P1 (1), pin k
(3) and harness 1235493 circuit 779 terminal E4 on
battery negative terminal.
3.
Measure resistance between 12354593 P1 (1), pin f (4) and
harness 12354672 circuit 773 terminal E2 on starter.
4.
Does MSD read more than one ohm either time?
2YN
1.
Replace MSD/ICE distribution
box (WP 0874 00, WP 0875 00,
or WP 0877 00).
2.
Verify no faults found.
014900-2
Change 5