TM 9-2350-277-20-1
MSD/ICE TEST 70 STARTER SOLENOID VOLTAGE DIAGNOSTIC
TROUBLESHOOTING
0150 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
Electrical Connector Pliers (WP 0926 00, Item 31)
MSD/ICE Test Set (WP 0926 00, Item 61)
Jumper Wire
Personnel Required
Mechanic
References
TM 9-6625-2301-14&P
TM 9-2350-277-10
Equipment Condition
Engine stopped (TM 9-2350-277-10)
Carrier blocked (TM 9-2350-277-10)
Power plant access door open (TM 9-2350-277-10)
Driver’s power plant access panel removed
(WP 0441 00)
T
1.
Remove plug W1 P1 from MSD jack J1.
2.
Hook up MSD to carrier batteries. See TM 9-6625-2301-14&P.
3.
Set up Test 89. See TM 9-6625-2301-14&P.
4.
Turn MASTER SWITCH ON. See TM 9-2350-277-10.
5.
Measure voltage between W1 P1 (1), pins S (+) (2) and M (–) (3).
6.
Does MSD read 0 volts?
TN
1.
Faulty MSD.
2.
Notify supervisor.
015000-1
Change 5