TM 9-2350-277-20-5
REPLACE M3 NBC HEATER HOSES AND FITTINGS (M113A3 AMBULANCE ONLY) —
Continued
0784 00
30. Install clamp (10) and patient’s lower right outlet hose (11) on lower right heater (12), three spring clips (1), and right
bracket (4). Tighten clamp.
FOLLOW-THROUGH STEPS
1.
Connect battery ground strap (WP 0337 00).
2.
Start engine (see your -10).
3.
Raise and lock ramp (see your -10).
4.
Stop engine (see your -10).
5.
Check air flow of NBC system. Follow procedures in TM 3-6680-316-10.
END OF TASK
0784 00-7/8 blank