MORTAR FIRE CONTROL SYSTEM (MFCS), M95/M96 (M577A3 AND
M1064A3) — Continued
0812 01
6)
Place the punch end (12) of the tang break-off tool (11) into the center of the helicoil insert (3), resting the tool
squarely on the insert tang (9).
7)
Strike the top of the tang break-off tool (11) with a sharp blow (using a soft-faced hammer) to break insert
tang (9) from installed helicoil insert (3).
8)
If needed, use long narrow tweezers to remove the insert tang (9) from insert hole.
END OF TASK