TM 9-2350-277-20-6
REPAIR POWER CONTROL ENCLOSURE FACEPLATE AND BRACKET
(M1068A3 ONLY) — Continued
0828 00
NOTE
All leads are secured to S2 with a screw and a washer. The art work shows the removal of
only one washer and one screw.
NOTE
Unless otherwise noted, retain all hardware for use during reinstallation.
22. Remove screw (42), lockwasher (41), and circuit 9E lead (40) from terminal 1 of toggle switch S2 (39).
23. Remove screw (42), lockwasher (41), and circuit 30A lead (43) from terminal 2 of toggle switch S2 (39).
24. Remove screw (42), lockwasher (41), and circuit 13C lead (45) from terminal 3 of toggle switch S2 (39).
25. Remove screw (42), lockwasher (41), and circuits 8D and 8F leads (50) from terminal 4 of toggle switch S2 (39).
26. Remove screw (42), lockwasher (41), and circuit 29A lead (44) from terminal 5 of toggle switch S2 (39).
27. Remove screw (42), lockwasher (41), and circuit 28C and 28F leads (46) from terminal 6 of toggle switch S2 (39).
28. Remove nut (49), lockwasher (48), locking ring (47), and toggle switch S2 (39) from faceplate (9).
082800-5
Change 5