TM 9-2350-277-20-6
REPAIR POWER CONTROL ENCLOSURE FACEPLATE AND BRACKET
(M1068A3 ONLY) — Continued
0828 00
NOTE
If replacing the cascade remote harness RPI (W15), verify the type inverter you have (15-pin or
25-pin) and check the Repair Parts and Special Tools List (RPSTL) (TM 9-2350-277-24P) to
identify which harness to order.
21. Install cascade remote harness RP1 or remote cable assembly (27) on faceplate (9) and secure with four screws (28) and
new locknuts (26).
22. Install circuit breaker CB2 (21), four screws (30), and new lockwashers (29) on faceplate (9).
23. Install circuit 36C lead (25), nut (24), lockwasher (23) on terminal 2 of circuit breaker CB2 (21).
24. Install circuit 31B lead (22), lockwasher (23), and nut (24) on terminal 1 of circuit breaker CB2 (21).
0828 00-10