TM-9-2350-277-20-6

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 6 OF 6

  TM-9-2350-277-20-6 - Page 84 of 487

TM 9-2350-277-20-6
REPAIR POWER CONTROL ENCLOSURE FACEPLATE AND BRACKET
(M1068A3 ONLY) — Continued
0828 00
NOTE
All circuit leads for CB3 and CB4 are secured with a washer and a nut. The art work shows the
installation of only one washer and one nut.
16. Install circuit breakers CB3 (31) and CB4 (32) on faceplate (9) and secure with four screws (19) and new lockwashers
(20).
17. Install circuits 13B and 13C leads (37), lockwasher (34), and nut (35) on terminal 2 of circuit breaker CB4 (32).
18. Install circuit 12A lead (38), lockwasher (34), and nut (35) on terminal 1 of circuit breaker CB4 (32).
19. Install circuits 13B and 13A leads (36), lockwasher (34), and nut (35) on terminal 2 of circuit breaker CB3 (31).
20. Install circuit 11A lead (33), lockwasher (34), and nut (35) on terminal 1 of circuit breaker CB3 (31).
082800-9
Change 5