TM-9-2350-277-34

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

  TM-9-2350-277-34 - Page 816 of 871

TM 9-2350-277-34
REPAIR FAN AND GENERATOR VARIABLE SPEED DRIVE (OLD
CONFIGURATION) — Continued
0115 00
32. Lubricate new preformed packing (11) and install on generator pulley (12).
33. Install key (13) on shaft (14).
34. Install generator pulley (12) on fan pulley (15). Secure with screw (16) and washer (17). TIGHTEN SCREW TO 76-79
LB-FT (103-108 N·m) TORQUE.
FOLLOW-THROUGH STEPS
1.
Install fan and generator variable speed drive assembly (see your -20).
END OF TASK
0115 00-13/14 blank