2--12 PREPARATION FOR FIRING — CONTINUED
2--12.2
Boresighting — Continued
f.
Comparison Test of the M140/M140A1 Alinement Device — Continued
NOTE
Correct azimuth reading is 3200 mils.
4
To determine which M140/M140A1 alinement device (27) is unserviceable, obtain a third M140/M140A1
alinement device and check boresight of weapon again.
5
Without changing azimuth reading, install each of the other two M140/M140A1 alinement devices (27).
The M140/M140A1 alinement device on which reticles will not aline with M117/M117A2 panoramic
telescope (18) reticle is defective. Turn in defective M140/M140A1 alinement device to unit
maintenance for repair.