TM-9-2350-311-20-1

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL FOR HULL, POWERPLANT, DRIVE CONTROLS, TRACKS, SUSPENSION, AND ASSOCIATED COMPONENTS

AUGUST 1994

  TM-9-2350-311-20-1 - Page 1213 of 1275

TM 9-2350-311-20-1
- Check all battery electrolyte levels.
- Clean all battery terminals.
- Check batteries’ specific gravities (para 8-28).
- Charge batteries if they haven’t already been charged.
- Clamp current probe, TK item 11, around battery cable that connects series pair of batteries.
Make sure current probe is closed.
- Point arrow on current probe toward negative post as shown in paragraph 1-11.
- Engage starter only long enough to briefly turn engine (approximately 1 second).
Refer to TM 9-4910-571-12&P for
offset fault isolation.
Figure 3, Sheet 10 of 36
I-36
Go to step 3, Figure 3,
sheet 24.


Back to Top