TM-9-2350-311-20-1

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL FOR HULL, POWERPLANT, DRIVE CONTROLS, TRACKS, SUSPENSION, AND ASSOCIATED COMPONENTS

AUGUST 1994

  TM-9-2350-311-20-1 - Page 1215 of 1275

TM 9-2350-311-20-1
If battery fails in
freezing weather,
crank engine for 5
seconds and retest.
This will warm
battery slightly.
Go to step 4,
Figure 3, sheet 13.
Check battery connections
and repeat step 3, Figure
3, sheet 11.
If display shows GO, check cables and
connections to starter and repeat step 3,
Figure 3, sheet 11.
If display shows .9.9.9.9, clean and tighten
connections on battery and repeat step 3,
Figure 3, sheet 11.
Go to NG 24, step 4, Figure 3, sheet 17
to test individual batteries of series of
batteries that failed test 75.
- Go to step 1, Figure 3, sheet 10 to perform
test on next series of batteries.
- Then go to NG 24, step 4 Figure 3, sheet 17
to perform test of individual batteries of this
failed series of batteries.
Figure 3, Sheet 12 of 36
I-38
NOTE