TM 9-2350-311-20-1
3-3 TROUBLESHOOTING CHART — CONTINUED
s.
FUEL LEVEL INDICATOR CIRCUIT —
(3) FUEL LEVEL INDICATOR (GAGE) SHOWS LEVEL
CONTINUED
FOR LOWER FUEL TANK, BUT NOT FOR UPPER
FUEL TANK
T00ls
General mechanic’s tool kit (item 64, Appx H)
Engine access door open (TM 9-2350-311-10)
Multimeter (item 36, Appx H)
Transmission access doors open (TM 9-2350-311-10)
TA-1 probe kit (item 43, Appx H)
Portable instrument panel cover removed (para 8-17)
(Long test leads may be needed for some tests;
Drivers instrument panel cover removed (para 8-17)
16 AWG wire maybe used as an extension.)
Fuel tanks full (TM 9-2350-311-10)
1. Place FUEL GAGE switch in LOWER position.
A
2.
3.
4.
5.
6.
Disconnect lead 31 from lower fuel tank
transmitter.
Turn MASTER switch ON and check FUEL
LEVEL gage for a reading.
If FUEL LEVEL gage shows a maximum
reading, place a jumper wire from lead 31 to
ground.
Check gage for reading.
Turn MASTER switch OFF.
Does FUEL LEVEL gage show minimum when
grounded and maximum when not grounded?
Replace lower fuel tank transmitter
(para 6-3).
I
B
1. Reconnect lead 31 to lower fuel tank
.
2.
3.
4.
5.
6.
transmitter.
Place FUEL GAGE switch in LOWER position.
Disconnect lead 31 from FUEL GAGE switch.
Place red lead of multimeter in FUEL GAGE
switch and black lead to ground.
Turn MASTER switch ON and check for
voltage.
Turn MASTER switch OFF.
Is voltage present?
I
CONTINUED ON NEXT PAGE
3-236
M109A4/M109A5 (ENGINE MODEL 7083-7396) SHOWN