TM 9-2350-311 -20-1
3-3 TROUBLESHOOTING CHART — CONTINUED
t.
DOME LIGHT CIRCUIT— CONTINUED
DOME LIGHT FAILS TO OPERATE; ALL OTHER LIGHTS
OPERATE
Tools
General mechanic’s tool kit (item 64, Appx H)
Multimeters (item 36, Appx H)
TA-1 probe kit (item 43, Appx H)
NOTE
Move dome light switch to both positions. If dome light
comes on in one position only, go to step F.
Disconnect lead 38 from dome light.
2. Place red lead of multimeters in lead 38 and
black lead to ground.
3. Turn MASTER switch ON and check for
voltage.
4. Turn MASTER switch OFF.
I
Is voltage present?
Go to step D.
CONTINUED ON NEXT PAGE
3-240