TM 9-2350-311-20-1
CONTINUED FROM STEP A
I
NOTE
In the following step, if B.O. light is out, place red lead
of multimeters on switch terminal (1). If white light is out,
place red lead of multimeters on switch terminal (2).
1. Reconnect lead 38 to dome light.
2. Remove cover from dome light (para 8-27).
3. Place red lead of multimeters on output
terminal (1 or 2) of dome light switch and
black lead to ground.
4. Turn MASTER and dome light switches ON
and check for voltage.
5. Turn dome light and MASTER switches
OFF.
Is voltage present?
1. Remove lamp from lamp assembly.
2. Place red lead of multimeters on contact in
center of socket and black lead to ground.
3. Turn MASTER and dome light switches ON
and check for voltage.
4. Turn dome light and MASTER switches
OFF.
Is voltage present?
Replace lamp (para 8-27).
I
Replace lamp assembly (para 8-27).
3-241