14
15
16
TM 9-2350-311-20-1
Disconnect power cable (starter and master warning circuit) (item 11, Appx H) (162) from master circuit wiring
harness 12268100 (M109A2/M109A3) or 12268418 (M109A4/M109A5) connector (118).
Disconnect power cable (starter circuit) (item 34, Appx H) (M109A2/M109A3) or (item 10, Appx H) (M109A4/
M109A5) (161) from starter cable 11593782 (M109A2/M109A3) or 12353401 (M109A4/M109A5) connector
(117).
Disconnect rectifier-to-voltage regulator lead 11593806 (M109A2/M109A3) or 12268303 (M109A4/M109A5)
(78) from rectifier (158).
,