TM 9-2350-311-20-1
b. Installation
1
2
3
4
5
NOTE
A good ground is essential to prevent radio static and to permit starter relay and bilge
pump to operate.
Install voltage regulator (3) on mount (8).
Install strap (13).
Install four flat washers (10), four new lockwashers (11), four voltage regulator mounting screws (9), and four
nuts (12).
Install mount (8) with regulator (3), four flat washers (5), four new lockwashers (6), four screws (4), and four
nuts (7).
Install two wiring harness connectors (1 and 2) at voltage regulator (3).
NOTE
FOLLOW-ON MAINTENANCE:
Connect batteries (para 8-28)
8-4 RECTIFIER (M109A2/M109A3)
This task covers:
a. Removal
b. Installation
M109A2/M109A3
Lockwashers (2) (item 81, Appx G)
Preformed packing (item 60, Appx G)
T
OO
I
S
Silicone compound (item 31, Appx D)
General mechanic’s tool kit (item 64, Appx H)
Torque wrench (item 72, Appx H)
Equipment Conditions
Batteries disconnected (para 8-28)
8-11