TM-9-2350-311-20-2

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL FOR CAB, ARMAMENT, SIGHTING AND FIRE CONTROL, ELEVATING AND TRAVERSING SYSTEMS AND ASSOCIATED COMPONENTS

DECEMBER 1993

  TM-9-2350-311-20-2 - Page 226 of 828

TM 9–2350–311–20–2
3–114
3–3
TROUBLESHOOTING — CONTINUED
i.
INTERCOMMUNICATION SYSTEM
— CONTINUED
(3)
DRIVER CANNOT COMMUNICATE.
— CONTINUED
CONTINUED FROM STEP N
CONTINUED ON NEXT PAGE
1.
Place one multimeter lead in socket H of J801 or
J804 connector and other lead to pin C of J803
connector.
2.
Check for continuity.
Is continuity present?
O
yes
no
Replace control box (para
8–16).
P
Check ground connection
of control box and repeat
step P. If malfunction per-
sists, replace control box
(para 8–16).
yes
no
1.
Place one multimeter lead in socket A of J801 or
J804 connector and other lead to ground.
2.
Check for continuity.
Is continuity present?
DRIVER’S CONTROL BOX
J801 OR
J804 CONNECTOR
SOCKET A
+–
DRIVER’S CONTROL BOX
+
J801 OR J804
CONNECTOR
SOCKET H
J803 CONNECTOR
PIN C