TM 9–2350–311–20–2
3–105
Replace amplifier
AM1780/VRC (para 8–16).
END OF TASK
Replace cable CX4720
(para 8–16).
yes
no
E
CONTINUED FROM STEP D
CABLE CX4720
SOCKETS A AND B
1.
Reconnect power relay box to intercom power
supply harness to cable CX4720.
2.
Disconnect cable CX4720 from J508 connector
at amplifier AM 1780/VRC.
3.
Turn MASTER switch to ON.
4.
Place red multimeter lead in socket B and black
lead in socket A.
5.
Check for voltage.
Is battery voltage present?
J508
AMPLIFIER
AM 1780/VRC
+–