TM 9–2350–311–20–2
19–2
19–1 REPLENISHER ACCUMULATOR ASSEMBLY
This task covers:
Servicing with High Pressure Nitrogen
INITIAL SETUP
Tools
Nitrogen charging kit (item 3, App. H)
Purging kit, fire control (item 4, Appx H)
Materials/Parts
Dry nitrogen (item 22, Appx D)
Soap (item 33, Appx D)
Servicing with High Pressure Nitrogen
WARNING
Make sure charging cylinder contains dry nitrogen. Dry nitrogen tanks are marked with one or two
black bands. Certain other gases can cause accumulator to explode, resulting in possible injury and
equipment damage.
CAUTION
Under no circumstances exceed the pressures indicated in the following procedures to prevent
damage to equipment.
NOTE
Fire control charging kit is used to charge accumulator replenisher assembly to obtain low pressure
required.
1
To set up fire control charging equipment, remove protective cover (1) from shutoff valve (2).
2
Open shutoff valve (2) momentarily to rid valve seat of any foreign matter.
3
Attach regulator (3) securely using adapter (4).
3
4
2
1