TM 9--2520--215--34
0063 00--2
TORQUE CONVERTER PUMP ASSEMBLY REPLACEMENT – CONTINUED
0063 00
INSTALLATION
1. Install torque converter pump assembly (4) and stator assembly (3) on ground sleeve (2).
2. Install nut (1), flat side first, onto ground sleeve (2). Torque nut (1) to 300 lb--ft (406.8 N
S
m). Stake thin outer lip
of nut (1) into two opposite grooves in ground sleeve (2).
NOTE
FOLLOW--ON MAINTENANCE:
Install torque converter turbine shaft
assembly (WP 0067 00)
END OF WORK PACKAGE