TM 9-2520-246-34-1
FRAME 5
NOTE
Readings must be within limits given in table 2-52.
The letter T indicates a tight fit. If readings are
not within given limits,
throw away part and get
a new one.
1.
Measure diameter of dowel pin (1).
2.
Measure dowel pin bore (2).
3.
Measure fit of dowel pin (1) in bore (2).
GO TO FRAME 6
Index Number
1
2
1 and 2
Table 2-52.
Transfer Case Dowel Pin Wear Limits
Item/Point of Measurement
Dowel pin diameter
Dowel pin bore
Fit of dowel pin in bore
Size and Fit
of New Parts
(inches)
0.7500 to 0.7510
0.7461 to 0.7472
0.0028T to 0.0049T
Wear Limit
(inches)
None
0.7480
0.0020T
2-213