TM 9-2520-246-34-1
FRAME 9
1.
Measure fit of
2.
Measure fit of
3.
Measure fit of
GO TO FRAME 10
NOTE
Readings must be within limits given in table 2-56.
The letter T indicates a tight fit. If readings are
not within given limits, throw away part and get
a new one.
oil seal (1) in bore (2).
oil seal (3) in input shaft cover bore (4).
deflector (5) on flange (6).
Index Number
l and 2
3 and 4
5 and 6
Table 2-56.
Input Shaft Cover Fits and Tolerances
Item/Point of Measurement
Fit of oil seal in bore
Fit of seal in input shaft cover
Fit of deflector on flange
Size and Fit
of New Parts
(inches)
0.0024T to 0.0078T
0.0038T to 0.0098T
0.0020T to 0.0100T
Wear Limit
(inches)
0.0015T
0.0025T
0.0010T
2-217