TM 9-2520-270-34
CAUTION
Second range directional control
slide bore in valve are precision
slide and
fit parts.
Do not drop, scratch, or nick slide. Equipment
can be damaged.
3. REMOVE DIRECTIONAL CONTROL
SLIDE (1), SPRING (2), AND
RETAINER (3).
7. CHECK HOUSING (5).
a. Using small hole gage set and
micrometer caliper set, measure
diameter of bore (6) in both ends
of housing (5). Do not measure
threads.
b. If either measurement is more than
0.5009 inch (12.723 mm), replace valve
assembly and go to END OF TASK.
If not, go to step 8.
4.
5.
6.
USING RETAINING-RING PLIERS,
REMOVE AND DISCARD RETAINING
RING (4).
CLEAN SECOND RANGE RELAY
VALVE ASSEMBLY.
a. Clean housing and piece parts. See
page 2-2.
INSPECT SECOND RANGE RELAY
VALVE ASSEMBLY.
a. Inspect housing and piece parts.
page 2-5.
See
8. CHECK SPRING (2).
a. Using indicator caliper, measure free
length of spring (2), Replace spring
if free length is less than 0.90 inch
(22.86 mm).
4-522
Change
1