TM 9-2520-270-34
9. CHECK SLIDE (1).
a. Using micrometer caliper set,
measure diameter of slide (1) in
two places.
b. Replace slide (1) if either measure-
ment is less than 0.4992 inch
(12.680 mm).
11. INSTALL RETAINER (3), SPRING (4),
AND SLIDE (1).
ASSEMBLE
10. USING RETAINING-RING PLIERS,
INSTALL NEW RETAINING RING (2)
WITH SHARP SIDE OUT.
12. CHECK THAT SLIDE (1) MOVES
FREELY IN BORE (5).
a. Push slide (1) in and out of bore (5)
several times.
b. If slide (1) moves freely in bore (5),
go to step 13. If not, go to step 3.
GO TO NEXT PAGE
Change
1
4-523