TM 9-2520-270-34
a.
b.
c.
d.
9. REMOVE PRESSURE EQUALIZING
VALVE (1) FROM UPPER
CONTAINER (2).
Remove screw (3) and lock
washer (4) from retainer (5).
Remove wire rope (6) from
retainer (5).
Using spanner wrench, unscrew
valve (1) from dessicant port (7) in
upper container (2).
Remove preformed packing (8) from
valve (1). Discard packing.
10. REMOVE NUT (9), WASHER (10), AND
VALVE (1) FROM ACCESS COVER (11).
a. Using 1-inch drive ratchet and
2 1/4-inch socket, remove nut (9).
b. Remove washer (10) and valve (1)
from cover (11).
c. Remove gasket (12) from cover (11).
Discard gasket (12), if damaged.
4-530
Change 1