TM-9-2520-272-40

CROSS-DRIVE TRANSMISSION WITH CONTAINER MODEL X200-4A

TECHNICAL MANUAL; SUSTAINMENT MAINTENANCE MANUAL

FEBRUARY 2012

  TM-9-2520-272-40 - Page 82 of 620

TM 9-2520-272-40
0010
REMOVE LOCKUP CONTROL VALVE ASSEMBLY
NOTE
Top cover assembly is removed from transmission.
Control valve assemblies are removed with solenoids attached.
Wiring harness does not have to be removed to remove lockup control valve assembly.
Transmission is upright on foororworktab
le
.
No solenoid should be removed from control valve assemblies unless procedures have
established that solenoid malfunction exists.
When necessary to replace a solenoid or to repair solenoid connector, refer to Replace
Solenoids and Terminals, WP 0070.
1. Remove two 5/16-20 x 2-1/4 inch bolts (Figure 1, Item 1) and washers (Figure 1, Item 2) that attach lockup
control valve assembly (Figure 1, Item 4) to separator plate (Figure 1, Item 5).
2. Remove four 5/16-18 x 2-3/4 inch bolts (Figure 1, Item 3) and washers (Figure 1, Item 2) that attach lockup
control valve assembly (Figure 1, Item 4) to separator plate (Figure 1, Item 5).
3. Disconnect plastic connectors that attach wiring harness to solenoids.
4. Remove lockup control valve assembly (Figure 1, Item 4).
0010
2


Back to Top