TM 9-2540-207-14&P
5-86
Figure 5-20. Installing New Fuel Lines
2.
Position the Fuel Pump into the Top Housing and connect the two (2) fuel lines to the
Burner Fan Plate Assembly fuel fittings in accordance with the previous step.
Note: The fuel lines attached to the pump should be facing towards the
center of the Top Housing.
Note: P80, or DF2 may be used as a lubricant to aid installing the fuel lines.
3.
Apply Loctite 243 (blue) to the two (2) machine screws.
4.
Using a #2 cross-tip screwdriver, secure the Fuel Pump in place with the two (2) screws,
flat washers, and star washers.
5.
Attach Wiring Harness connector (J4) to the Fuel Pump ensuring the connector locking
tab is properly engaged.
6.
Using a 9/16" open ended wrench, connect the fuel supply to the heater.
7.
Connect vehicle power cable to the heater MS Power connector (Control Box
Connection).
8.
Start the heater and check that there are NO fuel leaks from the fuel connections (ref.
Figure
5.5-9).
9.
Install Top Cover (ref. 5.4.1).