CLEANING - Continued
WARNING
Cleaning solvent is TOXIC and flammable. Wear protective goggles and gloves; use only
in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not breathe
vapors. Keep away from heat or flame. Never smoke when using cleaning solvent. Failure
to comply may result in injury, illness, or death to personnel.
8.
Clean oil cooler housing and cover with cleaning solvent and dry with compressed air.
END OF TASK
TEST AND INSPECTION
WARNING
Protect personnel against any stream of pressurized water from a leak or rupture of a
fitting, hose, or oil cooler during high-pressure air-leak test. Failure to comply may result in
injury to personnel.
1.
Install rubber gasket (Figure 4, Item 42), fabricated blocking plate (Figure 4, Item 41), 10-5/16 inch diameter
screws (Figure 4, Item 45), flat washers (Figure 4, Item 44), and nuts (Figure 4, Item 43) from pressure
testing kit (WP 0081, Figure 6) on transmission oil cooler (Figure 4, Item 33) or engine oil cooler
(Figure 4, Item 19).
2.
Connect air line to blocking plate (Figure 4, Item 41) and apply pressure of 75 PSI (517 kPa) to oil cooler.
TM 9-2815-205-24
0021