MEASUREMENTS - CYLINDER LINER - Continued
2.
Install liner in proper bore of cylinder block. Using cylinder bore gage (Figure 4, Item 4), measure cylinder
liner inside diameter at 14 places (Figure 4, Items C thru I) on (XZ) and (WY) axes. Refer to Table 1 for
location of measurement.
Table 1.
Location of Cylinder Liner Inside Diameter Measurement.
MEASUREMENT
DISTANCE FROM TOP EDGE
C
0.0 in. (0.0 mm)
D
1.0 in. (25.4 mm)
E
1.75 in. (44.5 mm)
F
3.5 in. (88.9 mm)
G
5.0 in. (127.0 mm)
H
7.0 in. (177.8 mm)
I
9.0 in. (228.6 mm)
C
D
W
Y
X
Z
E
F
G
H
I
4
MAINT_390
Figure 4.
Cylinder Bore Gage.
TM 9-2815-205-24
0096
0096-5