TM 9-2815-210-34-2-2
FRAME 21
1.
2.
3.
NOTE
Readings must be within limits given in table 4-41. The
letter L shows a loose fit.
If readings are not within
given limits, get a new oil pump.
Measure depth of pressure pump drive impeller bore (1).
Measure length A of pressure pump drive impeller (2).
Subtract measurement in step 1 from measurement in step 2. Result is
clearance between pressure pump drive impeller (2) and top of pressure
pump drive impeller bore (1).
GO TO FRAME 22
NOTE: CHECK ONLY THOSE PARTS WHICH ARE CALLED OUT IN THIS
FRAME. PARTS WITHOUT CALLOUTS ARE SHOWN ONLY FOR
REFERENCE PURPOSES OR ARE CHECKED IN ANOTHER FRAME.
TA 113630
Index
Number
1
2
1 and 2
Table 4-41. Engine LDS-465-2 Pressure Pump Drive Impeller
and Drive Impeller Bore Wear Limits
Item /Point of Measurement
Pressure pump drive impeller
bore depth
Pressure pump drive impeller
length A
Clearance between pressure
pump drive impeller and top
of drive impeller bore
Size and Fit
of New Parts
(inches)
1.5600 to 1.5620
1.5565 to 1.5580
0.0020L to 0.0055L
Wear Limit
(inches)
1.5635
1.5560
0.0075L
max
4-185